Gasket Maintenance
One of the biggest keys to getting peak performance from
your pellet unit is gasket maintenance. Our pellet units are designed to
pull combustion air in through the fire and eject the exhaust out through
the vent pipe.
The gaskets which seal around the window (AC-GGK), the
door (AC-DGKC) and the hopper lid
(PU-HLG) ensure that the air that is
pulled through the stove is not pulled through these areas. Air that enters
through leaky gaskets is air that does not pass through the fire,
leading to incomplete burning of the fuel and diminished performance.
Some gaskets are
only going to need replacing when the component they are sealing is removed.
these would include the burn pot gasket (PU-BPG), the combustion blower
gasket (PU-CBG), and the auger bearing gaskets
(PU-ABG).
|
Links for Replacement Gaskets
Click here for Online Store or choose a link below
 |
Click on the Picture for
"AC-GGK"Window Glass Gasket Kit
|
 |
Click on the Picture for
"AC-DGKC"Door Gasket Kit
|
 |
Click on the Picture for
"PU-HLG"Hopper Lid Gasket |
|