Dry Run Checkout
To ensure proper operation of the pellet unit before placing
the unit into normal use, a "Dry Run" checkout should be performed.
Press the "ON" button to begin the dry run.

The control board will display number settings in the
display window for several seconds then the letters "S-U" will appear. the
unit will begin functioning at this time. While the unit is running ,observe
the following: the exhaust blower should be running, the bottom auger
(appearing in the firebox) should be running continuously, and the top auger
(in the hopper) should run for a few seconds then stop for several seconds
and repeat this cycle as the unit runs, after a few minutes time , the
igniter element should start to glow visibly in a hole in the back right of
the burn pot.
After the 20 minute dry run, the control board will return
to "OFF." An error code will appear in the Heat Range and the Blower Speed
windows as " E-2",
which means the unit failed to start normally. Note: if the room temperature is warmer than 75 degrees when this test is run, the stove may
not give an "E-2" as but will go into shutdown after an additional
several minutes. if this happens it is also an acceptable result for the dry run.

After this code is received
and you are sure the unit is working properly, the unit may be fueled and
placed into operation.
|
If you
have any further questions or concerns, please contact Customer Service at:
1-800-245-6489
|
|
|
|
Copyright © 2005
England's Stove Works, Inc. All rights reserved. Revised:
11/07/2008
|
|
This web site, including all pictures, description
and information of any sort contained therein is intended for the sole use
of customers and representatives of England's Stove Works, Inc. No part of
this web site or the information contained therein may be reproduced
without express written permission from England's Stove Works,
Inc..
|
|