Dry Run Checkout

To ensure proper operation of the pellet unit before placing the unit into normal use, a "Dry Run" checkout should be performed.

Press the "ON" button to begin the dry run.

                                                                               

The control board will display number settings in the display window for several seconds then the letters "S-U" will appear. the unit will begin functioning at this time. While the unit is running ,observe the following: the exhaust blower should be running, the bottom auger (appearing in the firebox) should be running continuously, and the top auger (in the hopper) should run for a few seconds then stop for several seconds and repeat this cycle as the unit runs, after a few minutes time , the igniter element should start to glow visibly in a hole in the back right of the burn pot.

After the 20 minute dry run, the control board will return to "OFF." An error code will appear in the Heat Range and the Blower Speed windows as "E-2", which means the unit failed to start normally.   Note: if the room temperature is warmer than 75 degrees when this test is run, the stove may not give an "E-2" as  but will go into shutdown after an additional several minutes. if this happens it is also an acceptable result for the dry run.

    

After this code is received and you are sure the unit is working properly, the unit may be fueled and placed into operation.

If you have any further questions or concerns, please contact Customer Service at:
1-800-245-6489

Copyright © 2005   England's Stove Works, Inc.   All rights reserved.
Revised:  11/07/2008

This web site, including all pictures, description and information of any sort contained therein is intended for the sole use of customers and representatives of England's Stove Works, Inc. No part of this web site or the information contained therein may be reproduced without express written permission from England's Stove Works, Inc..