Diagnostic Test Mode
Units built from 2004 to present have a
diagnostic test mode built into the circuit board. This can be used to test
the individual electrical components of the unit.
|
Warning:
|
This mode can not be used to operate the stove! Attempting to burn this unit in this mode
can cause damage to the unit.
|
| Note: |
The stove
should be completely empty of fuel and cold when using the diagnostic mode for testing the unit. |
 |
| 1. |
Unplug the stove. Locate the
low burn air
and air on temp buttons at the bottom of the touch pad.
To start diagnostic, plug in the stove and then quickly push these buttons at the same time, then release |
|
 |
| |
A number code will appear in the digital readout, this is the reading for the heat sensor. The blower speed number may change some while displayed. This is normal. |
|
 |
| 2. |
At this point press the
low burn air button
located at the bottom center of the touchpad. After pushing
a dash appears in each of the two display windows. |
|
 |
| 3. |
Press the
blower speed up arrow , and release, the exhaust blower will
come on and you should see a circle in the blower speed and a dash in the heat range. |
|
 |
| 4. |
Next, press the
blower speed down arrow
, this will turn on the room air blower and you will see in
the display an 8 in the blower speed and the dash in the heat
range |
|
 |
|
5. |
Press the
heat range up arrow
next, this will start the feed auger
motor, you will see an 8 in both displays at this time. |
|
 |
| 6. |
The
low burn air button at the bottom center of the control
board will turn on the auto igniter element, and the red light above the button will light up when pressed, look through the glass in the front door
and watch for 2 to 3 minutes for the igniter to start to glow. |
|
| |
| 7. |
To turn off any of these components
simply push again the same button that turned it on . To take
the unit out of diagnostic mode, unplug the unit and plug it
back in, this will reset the control board back into its "run
mode". |
|
|
If you
have any further questions or concerns, please contact Customer Service at:
1-800-245-6489
|
|
|
|
Copyright © 2005
England's Stove Works, Inc. All rights reserved. Revised:
03/29/2007
|
|
This web site, including all pictures, description
and information of any sort contained therein is intended for the sole use
of customers and representatives of England's Stove Works, Inc.
No part of
this web site or the information contained therein may be reproduced
without express written permission from England's Stove Works, Inc..
|
|