Problem |
Cause |
Solution |
| 1. Auger not turning |
1. Loose set screw
2. Bad gear motor
3. Foreign matter in auger
4. Vacuum sensor |
1. Tighten setscrew on collar
2. Replace auger motor
3. Remove pellets and object
4. Check exhaust blower
|
| 2. Smoke smell or dust in house |
1. Improper exhaust
connection |
1. Check all connections for leaks
especially the exhaust blower
connection; Seal with silicone,
hose clamp or aluminum tape
|
| 3. Room air blower not
operating |
1. Loose sensor |
1. Tighten connection on sensor
|
| 4. Exhaust blower not
operating |
1. Loose connection
2. Bad blower
3. Bad vacuum sensor
|
1. Check connection at c/board
2. Replace blower
3. Replace vacuum sensor
|
5. Lazy fire
|
1. Control board settings
2. Bad exhaust blower
3. Excessive fuel moisture
4. Excessive ash
5. Low quality fuel
|
1. Review board settings
2. Replace blower
3. Keep fuel inside
4. Remove baffles; Clean unit
5. Use premium pellets and corn
|
6. Blown fuse (5 AMP)
|
1. Power surge
2. Exposed wire
3. Electric motor shorting
or bound up |
1. Replace fuse; use surge
protector
2. Check for exposed or frayed
wire and loose connections
3. Check motors and blowers
bound up for obstructions or
lock-up
|
| 7. High fuel consumption |
1. Low quality fuel
2. Board out of adjustment
|
1. Use premium fuel
2. Check c/board settings
|
| 8. Squeaking noise |
1. Build-up in tube
2. Improper auger alignment
3. Blower noise
|
1. Remove auger and clean
2. Re-align auger
3. Remove and oil blower
|
| 9. Pinging or rattling noise |
1. Foreign material
2. Loose set screw
|
1. Check blower for material
2. Check impeller blower screw
|
11. Unit keeps shutting down
("E" codes on control board) |
1. Blocked flue
2. Blower failure
3. Improper installation*
|
1. Check for flue blockage (nests,
rodents, excess soot, etc.)
2. Check combustion blower
wires, then call Cust. Svc.
3. Check for loose flue/pipe
connections. Also be sure to have
proper Outside Air hook-up.
|